BrainAmp MR
Overview
BrainAmp MR: Superior solution for combining EEG and fMRI
Over the course of the last number of years the combination of EEG and fMRI to investigate the electrophysiological as well as the hemodynamic information of cerebral dynamics has become an extremely popular technique. The first BrainAmp MR system for EEG/fMRI simultaneous acquisition was manufactured by Brain Products almost 7 years ago and it represented a real technological breakthrough.
The extremely high data quality, ease of use, long lasting experience of our developers and the unparalleled scientific and technical support made the BrainAmp MR amplifier the first choice for researchers all over the world. Many scientific publications refer to EEG/fMRI coregistration studies performed with the BrainAmp MR systems.
Technical reasons for the great success achieved by Brain Products with this system are as follows:
The BrainAmp MR is a shielded amplifier which can be taken directly inside the MRI chamber and placed right behind the subject’s head. From the amplifier the digitized signal is sent via fiber optic cable to the USB interface located in the control room. Therefore no artifacts can be added along the way to outside of the MRI chamber. The short length required for the electrical cables used to connect the electrode cap with the amplifier complies with all safety requirements for the experimental subject.
The sturdy and compact BrainAmp MR can be stacked one on one to acquire up to 128 EEG channels with ease. The MR compatible rechargeable batteries make this system a truly portable solution even for outdoor recordings.
The BrainAmp MR can be combined with the MR compatible ExG amplifi ers to add the capability to record bipolar and peripheral signals (e.g. Galvanic Skin Response) in an extremely compact setup.










Technical Specifications
| Number of Channels per unit | 32 |
| Max. Number of channels | 128 |
| Reference Type | unipolar |
| MR-compatibility | Yes (for scanners up to 4 Tesla) |
| Bandwidth [Hz] | 0.016 to 250 |
| High Pass Filter [Hz] | 0.016 / 10 s AC |
| Low Pass Filter [Hz] | 1000 |
| Input Noise [μVpp] | < 1 |
| Input Impedance [MΩ] | 10 |
| Input Measurement Ground / Reference | Yes |
| A/D-C [bit] | 16 |
| A/D-Rate [Hz] | 5000 |
| Max. Sampling Frequency [Hz] | 5000 |
| Offset Compatibility [mV] | ± 300 |
| Operating Range [mV] | fix: ±16.384 |
| Resolution [μV] | fix: 0.5 |
| CMRR [dB] | ≥ 90 |
| TTL Trigger Input [bit] | 16 |
| Synchronized Digital Trigger Input [bit] | up to 16 |
| Max. Power Consumption [mA] | 160 |
| Power Supply | rechargeable Battery |
| Signal Transmission | optical |
| PC Interface | PCI, USB 2.0 |
| Deblocking Function | Yes |
| Blocking of Unused Channels | Yes |
| Safety | Twin Fiber optical Transmission Protection Class II, Type BF IEC EN 60601 EMC tested, electrically safe |
| Classification to MDD 93/42/EEC | Class IIa |
| Dimensions H x W x D [mm] | 68 x 160 x 187 |
| Weight [kg] | 1.1 |
To compare the technical specifications of all amplifiers please download this pdf file:
Type: pdf Size: 230.6 KB
Brochures
Type: pdf Size: 384.0 KB
Type: pdf Size: 327.9 KB
Type: pdf Size: 3.0 MB
Manual, Tutorials & Downloads (only for registered users)
Press Release Articles
2.2008
It is official now: BrainAmp MR series is the first Siemens audited system for combined EEG/fMRI worldwide!
by Dr. Robert Störmer, Technical Support
Type: pdf Size: 150.7 KB
3.2007
MR Artifact correction in coregistered EEG data ... (4)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 378.6 KB
3.2007
Important notice to users of BrainAmp USB adapter
by Dr. Robert Störmer, Technical Support
Type: pdf Size: 79.5 KB
2.2007
MR Artifact correction in coregistered EEG data ... (3)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 602.1 KB
2.2007
FREE real time Pulse Artifact correction module for BrainVision RecView
by Dr. Robert Störmer, Technical Support
Type: pdf Size: 99.8 KB
1.2007
MR Artifact correction in coregistered EEG data ... (2)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 519.5 KB
3.2006
MR Artifact correction in coregistered EEG data ... (1)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 436.8 KB
1.2006
RecView MRI-module: Full online quality control right during the scan
by Dr. Achim Hornecker and Dr. Robert Störmer
Type: pdf Size: 72.1 KB
7.2005
Brain Products: First company offering real „plug & play“ systems for continuous MR/EEG synchronization
by Alexander Svojanovsky, General Manager
Type: pdf Size: 185.2 KB
5.2005
BrainAmp MR making big impression on US market
by Ingmar Gutberlet, Ph.D., Customer Support Manager
Type: pdf Size: 255.9 KB
3.2005
BrainAmp MR/BrainAmp MR plus now available in the USA
by Alexander Svojanovsky, General Manager
Type: pdf Size: 326.0 KB
Related Products
Hardware
Software
Electrode Caps
Accessories
Product Certificates
Type: pdf Size: 862.0 KB
Type: pdf Size: 107.3 KB
International Products Approvals
Type: pdf Size: 1.2 MB
Type: pdf Size: 228.5 KB