BrainAmp MR plus
Overview
BrainAmp MR plus extends the borders of the technically possible
Since the design of the first BrainAmp MR, the neurophysiology research world moved forward and started to look at new techniques of investigating the brain in action. In light of this it was obvious that there was a need to develop a more advanced amplifier which could cover a wider range of applications and be as flexible as required by its users.
The BrainAmp MR plus enhances the already outstanding features of the BrainAmp MR thanks to the multiple hardware signal resolution options settable via the recording software. Based on the recording needs, with just one “click” it is possible to switch from AC to DC mode acquisitions as well as to extend the hardware bandwidth.
The result is an amplifier that can be placed inside of the MRI bore for simultaneous EEG/fMRI acquisitions as well as used in the EEG lab for EEG/TMS co-registrations, EEG/ERP studies and Brain Computer Interface applications. There is no need for different amplifier types as the Brain Products’ flagship represents the state of the art solution for all of the aforementioned applications.
BrainAmp MR plus systems can be stacked on top of each other to increase the number of available channels up to 128 for recordings in the MRI environment and up to 256 channels for laboratory applications. Powered with rechargeable batteries, this amplifier can be used in any environment even for outdoor recordings. The BrainAmp MR plus system can be combined with the BrainAmp ExG MR amplifier to record EEG, EOG, EMG, ECG, GSR (Galvanic Skin Response) and many other types of bipolar and auxiliary signals.










Technical Specifications
| Number of Channels per unit | 32 |
| Max. Number of channels | 128 (for use in fMRI) 256 (for use in other fields of application) |
| Reference Type | unipolar |
| MR-compatibility | Yes (for scanners up to 4 Tesla) |
| Bandwidth [Hz] | DC - 1000 |
| High Pass Filter [Hz] | 0.016 / AC or DC switchable |
| Low Pass Filter [Hz] | 1000 / 250 switchable |
| Input Noise [μVpp] | ≤ 1 |
| Input Impedance [MΩ] | 10 / 10000 |
| Impedance Measurement Ground / Reference | Yes |
| A/D-Conversion [bit] | 16 |
| Max. Sampling Frequency [Hz] | 5000 |
| Offset Compatibility [mV] | ± 300 |
| Operating Range [mV] | selectable: ±3.2768; ±16.384; ±327.68 |
| Resolution [μV] | selectable: 0.1; 0.5; 10.0 |
| CMRR [dB] | ≥ 110 |
| TTL Trigger Input [bit] | 16 |
| Synchronized Digital Trigger Input [bit] | up to 16 |
| Max. Power Consumption [mA] | 160 |
| Power Supply | rechargeable Battery |
| Signal Transmission | optical |
| PC Interface | PCI, USB 2.0 |
| Deblocking Function | Yes |
| Blocking of Unused Channels | Yes |
| Safety | Twin Fiber optical Transmission Protection Class II, Type BF IEC EN 60601 EMC tested, electrically safe |
| Classification to MDD 93/42/EEC | Class IIa |
| Dimensions H x W x D [mm] | 68 x 160 x 187 |
| Weight [kg] | 1.1 |
To compare the technical specifications of all amplifiers please download this pdf file:
Type: pdf Size: 304.3 KB
Brochures
Type: pdf Size: 384.0 KB
Type: pdf Size: 327.9 KB
Type: pdf Size: 3.0 MB
Manual, Tutorials & Downloads (only for registered users)
Press Release Articles
12.2009
New rTMS stimulation device PowerMAG research
by Alex Svojanovsky and Dr. Kerstin Wendicke, MAG & More GmbH
Type: pdf Size: 222.4 KB
10.2007
MR Artifact correction in coregistered EEG data ... (4)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 233.3 KB
10.2007
Important notice to users of BrainAmp USB adapter
by Dr. Robert Störmer, Technical Support
Type: pdf Size: 74.9 KB
5.2007
MR Artifact correction in coregistered EEG data ... (3)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 1.1 MB
5.2007
FREE real time Pulse Artifact correction module for BrainVision RecView
by Dr. Robert Störmer, Technical Support
Type: pdf Size: 238.8 KB
2.2007
MR Artifact correction in coregistered EEG data ... (2)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 516.7 KB
10.2006
MR Artifact correction in coregistered EEG data ... (1)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 657.5 KB
1.2006
RecView MRI-module: Full online quality control right during the scan
by Dr. Achim Hornecker and Dr. Robert Störmer
Type: pdf Size: 67.6 KB
10.2005
Brain Products: First company offering real „plug & play“ systems for continuous MR/EEG synchronization
by Alexander Svojanovsky, General Manager
Type: pdf Size: 77.5 KB
6.2005
BrainAmp MR making big impression on US market
by Ingmar Gutberlet, Ph.D., Customer Support Manager
Type: pdf Size: 494.7 KB
4.2005
BCI and Biofeedback during fMRI possible in MR Scanners of up to 7 Tesla
by Alexander Svojanovsky
Type: pdf Size: 301.6 KB
2.2005
BrainAmp MR/BrainAmp MR plus now available in the USA
by Alexander Svojanovsky, General Manager
Type: pdf Size: 453.9 KB
Related Products
Hardware
Software
Electrode Caps
Accessories
Manufacturer Certificates
Type: pdf Size: 138.9 KB
Product Certificates
Type: pdf Size: 862.0 KB
Type: pdf Size: 136.0 KB
International Products Approvals
Type: pdf Size: 362.4 KB