BrainAmp ExG MR
Overview
BrainAmp ExG MR: MR compatible bipolar amplifier with unparalleled design
The increasing interest in simultaneous EEG/fMRI recordings to investigate the brain’s activity very quickly led to the need to also co-register other types of physiological data such as bipolar and peripheral signals. The BrainAmp ExG MR bridges this gap and makes the recording of bipolar and polygraphic signals in the MRI environment a simple procedure.The magnetically shielded BrainAmp ExG MR system can be taken inside the magnet bore and placed right next to the experiment subject minimizing the length of the cables to meet all safety requirements.
The available MR compatible auxiliary sensors (GSR MR) are powered directly through the battery supplied amplifier which ensures patient safety and product portability.
The two existing versions with 8 or 16 channels can be purchased as extension to the BrainAmp MR and BrainAmp MR plus, but also as fully independent units.









Technical Specifications
| BrainAmp ExG MR 8 | BrainAmp ExG MR 16 | |
| Number of Channels per unit | 8 | 16 |
| Max. Number of channels | - | - |
| Reference Type | 8 bipolar (sensors cannot be connected!) |
16 bipolar OR 8 bipolar + 8 AUX (to connect sensors) |
| MR-compatibility | Yes (for scanners up to 4 Tesla) | Yes (for scanners up to 4 Tesla) |
| Bandwidth [Hz] | DC - 1000 | DC - 1000 |
| High Pass Filter [Hz] | 0.016 / AC or DC switchable | 0.016 / AC or DC switchable |
| Low Pass Filter [Hz] | 1000 / 250 switchable | 1000 / 250 switchable |
| Input Noise [μVpp] | ≤ 2 | ≤ 2 |
| Input Impedance [MΩ] | 10 / 10000 | 10 / 10000 |
| Impedance Measurement Ground / Reference | Yes | Yes |
| A/D-Conversion [bit] | 16 | 16 |
| Max. Sampling Frequency [Hz] | 5000 | 5000 |
| Offset Compatibility [mV] | ± 300 | ± 300 |
| Operating Range [mV] | selectable: ±3.2768; ±16.384; ±327.68 | selectable: ±3.2768; ±16.384; ±327.68 |
| Resolution [μV] | selectable: 0.1; 0.5; 10.0 | selectable: 0.1; 0.5; 10.0 |
| CMRR [dB] | ≥ 100 | ≥ 100 |
| TTL Trigger Input [bit] | 16 | 16 |
| Synchronized Digital Trigger Input [bit] | up to 16 | up to 16 |
| Max. Power Consumption [mA] | 160 | 160 |
| Power Supply | rechargeable Battery | rechargeable Battery |
| Signal Transmission | optical | optical |
| PC Interface | PCI, USB 2.0 | PCI, USB 2.0 |
| Deblocking Function | Yes | Yes |
| Blocking of Unused Channels | Yes | Yes |
| Safety | Twin Fiber optical Transmission Protection Class II, Type BF IEC EN 60601 EMC tested, electrically safe |
Twin Fiber optical Transmission Protection Class II, Type BF IEC EN 60601 EMC tested, electrically safe |
| Classification to MDD 93/42/EEC | Class IIa | Class IIa |
| Dimensions H x W x D [mm] | 68 x 160 x 187 | 68 x 160 x 187 |
| Weight [kg] | 1.1 | 1.1 |
To compare the technical specifications of all amplifiers please download this pdf file:
Type: pdf Size: 304.3 KB
Brochures
Type: pdf Size: 384.0 KB
Type: pdf Size: 327.9 KB
Type: pdf Size: 3.0 MB
Manual, Tutorials & Downloads (only for registered users)
Press Release Articles
10.2007
MR Artifact correction in coregistered EEG data ... (4)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 233.3 KB
10.2007
Important notice to users of BrainAmp USB adapter
by Dr. Robert Störmer, Technical Support
Type: pdf Size: 74.9 KB
5.2007
MR Artifact correction in coregistered EEG data ... (3)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 1.1 MB
5.2007
FREE real time Pulse Artifact correction module for BrainVision RecView
by Dr. Robert Störmer, Technical Support
Type: pdf Size: 238.8 KB
2.2007
MR Artifact correction in coregistered EEG data ... (2)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 516.7 KB
10.2006
MR Artifact correction in coregistered EEG data ... (1)
by Ingmar Gutberlet, Ph.D., Scientific Support Manager
Type: pdf Size: 657.5 KB
1.2006
RecView MRI-module: Full online quality control right during the scan
by Dr. Achim Hornecker and Dr. Robert Störmer
Type: pdf Size: 67.6 KB
10.2005
Brain Products: First company offering real „plug & play“ systems for continuous MR/EEG synchronization
by Alexander Svojanovsky, General Manager
Type: pdf Size: 77.5 KB
6.2005
BrainAmp MR plus ExG: True bipolar recordings inside the scanner
by Dr. Robert Störmer, Sales & Support
Type: pdf Size: 76.7 KB
Related Products
Hardware
Software
Accessories
Product Certificates
Type: pdf Size: 862.0 KB
Type: pdf Size: 136.0 KB
International Products Approvals
Type: pdf Size: 362.4 KB