actiCHamp series

Logo - Brain Products BrainVision actiCHamp Plus
  • Up to 160 channels: Maximum scalability with 32 channel modules

  • Integrated 8 additional AUX channels for sensors

  • Up to 100 kHz sampling rate

  • Full compatibility with all our active and passive electrode systems

actiCHamp Plus: Versatile all-in-one lab amplifier

actiCHamp Plus is a scalable and flexible amplifier solution for a wide range of laboratory EEG recording applications. It can be combined with all our active as well as passive electrode systems and is powered by a sturdy lithium-ion battery, the PowerUnit.

actiCHamp PlusAll electrode options to best fit your needs
    • Record with easy-to-prepare active electrodes (actiCAP slim/snap or actiCAP Xpress Twist) for best data quality
    • Easily switch to passive sponge-based electrodes (R-Net) when high channel counts and quick preparation times are crucial
    • Choose gel-based passive electrodes using our fully customizable BrainCaps
Scalable solution
    • Modularity for recording 32 to 160 channels
    • 8 additional AUX channels for including extra physiological sensors
    • Up to 100 kHz sampling rate
Highly integrated for multimodal recordings
    • Clock synchronization outputs allow for easy integration with external devices (e.g. TMS, EMG)
    • Forward incoming triggers to other signal acquisition systems (e.g. fNIRS)
Powered by lithium-ion technology (the PowerUnit)
    • Long battery life with low self-discharge rate
    • Extended recording times due to higher battery capacity

actiCHamp seriesTechnical specifications
Amplifier
Max. sampling rates for each channel combination:
     160 channels + 8 AUX25 kHz
     128 channels + 8 AUX25 kHz
     96 channels + 8 AUX25 kHz
     64 channels + 8 AUX50 kHz
     32 channels + 8 AUX100 kHz
Maximum number of channels160 EEG + 8 AUX
Maximum bandwidth of the EEG channelsDC up to 7,500 Hz
Digitization24-bit, one converter/channel
Input impedance (for DC)EEG channels: > 1,000 MΩ
AUX channels: As of Rev. 01: 40 MΩ
Input noise2 μVpp (DC – 35 Hz)
Input voltage range±400 mV (EEG), ±4.8 V (AUX)
ResolutionEEG channels: 0.819.2 V⁄(2^24 Bit)≈0.04883 μV/Bit
AUX channels: As of Rev. 02: 10 V/(2^24 Bit)≈0.596 μV/Bit
Common-mode rejection (CMR)100 dB (according to IEC 60601-2-26)
Trigger input8 bit
TTL (LVTTL) signals, 0 to +5 V (+ 3.3 V), max. 10 mA
Trigger output8 bit
TTL signals, 0 to +5 V, max. 10 mA
Use with active electrodesYes
Use with passive electrodesYes
Impedance measurementYes, three colors, displayed via LEDs for active electrodes
Easy replacement of faulty active electrodesYes, by removal from splitter box
Recording softwareBrainVision Recorder (version 1.22.0001 or later)
Integrated AUX/bipolar channels (base module)Yes, 8 AUX channels
Synchronization output3.5 mm stereo jack
TTL signal, always ON
Clock signal of A/D converter, based on the three basic sampling rates of the amplifier (10 kHz, 50 kHz, 100 kHz)
Dimensions (H x W x D)Approx. 68 mm x 160 mm x 187 mm
WeightApprox. 1.1 kg
Battery (PowerUnit)
Max. number of amplifiers1
Rated voltage6.6 V DC
Rated capacity13 Ah
Rated energy85.8 Wh
Output currentMax. 3 A
Rechargeable battery typeLithium-ion (lithium iron phosphate (LiFe-PO4))
Operating time for one amplifierMax. 16 hours (with a fully charged, new battery)
Charging timeTypically 12 hours with FRIWO charger (at room temperature with empty battery)
Typically 5 hours with Mascott charger (at room temperature with empty battery)
Dimensions (H x W x D)Approx. 68 mm x 160 mm x 187 mm
WeightApprox. 1.2 kg
State of charge (SOC) for transport< 30% of full capacity
State of charge (SOC) for storage30% up to 80% of full capacity
For longer storage periods:
Start with 80% SOC for extending the time period until SOC falls short of 30% by self-discharge
Miscellaneous
Suitable for use in MR scanner roomNo
Medical deviceNo
CE markingThe Brain Products GmbH confirms the electromagnetic compatibility (EMC) of this product according to the Directive 2014/30/ EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility.

The Brain Products GmbH confirms the RoHS compliance of this product according to Directive 2011/65/EU of the European Parliament and the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (recast published in the Official Journal of the European Union on 1 July 2011) as well as all its amendments up to and including the Commission delegated directive (EU) 2015/863 of 31 March2015 (published in the 0fficial Journal of the European Union on 4 June 2015).
EMC-tested in accordance with EN 61326-1:2013
(IEC 61326-1:2012)
Yes

Getting started

YouTube

By loading the video, you agree to YouTube's privacy policy.
Learn more

Load video

YouTube

By loading the video, you agree to YouTube's privacy policy.
Learn more

Load video

Recommended add-ons

TurboLink

TurboLink

actiCAP snap

actiCAP slim/snap

R-Net

R-Net

TriggerBox Plus

TriggerBox Plus

Sensors for the lab environment

Sensors for the lab environment

BIP2AUX adapter

BIP2AUX adapter