BIP2AUX adapter

BIP2AUX adapter
BIP2AUX adapter
  • Analogue differential DC amplifier for bipolar ExG recordings (e.g. ECG, EMG, EOG)

  • Has three 1.5 mm touch proof connectors for two signal electrodes (+ / -) and GND

  • Allows recording of bioelectrical signals by means of amplifier AUX inputs

  • Amplifies the incoming signal for high-quality data acquisition

BIP2AUX: Bipolar-to-auxiliary to add bipolar channels to your setup

The BIP2AUX adapter is a tiny, analogue differential DC amplifier that amplifies the incoming signal to optimize it for the auxiliary inputs of our amplifiers or their extensions (e.g. actiCHamp (Plus), Sensor and Trigger Extension for LiveAmp, BrainAmp ExG AUX Box). The adapter consequently turns our amplifiers into even more versatile research tools by making them able to also record bioelectrical signals with a bipolar montage (a common way of acquiring ExG signals, like EOG, ECG or EMG).

Although amplifiers like our actiCHamp and actiCHamp Plus have on-board inputs for auxiliary sensors, these inputs are intended to accept signals that typically lie in the voltage (V) range, whereas the amplitude of bipolar bioelectrical signals typically has values of just a few millivolts (mV). This mismatch may prevent that such signals are acquired at optimal quality.

Therefore, if you are interested in recording bioelectrical signals with a bipolar montage, adding the BIP2AUX adapter to your setup will for sure improve the quality of your recordings with our EEG amplifiers.

BIP2AUXTechnical specifications
Number of channels1 differential for EMG / ECG / EEG acquisition
Power supply±3 to ±5 V, max. 1 mA
Input range±50 mV
Output rangeNegative supply voltage +0.2 V to positive supply voltage -0.2 V
Virtual ground: 0 V output for 0 mV input
Differential impedance> 200 MΩ at DC
Analog gain100 ±3%
Frequency range0 to 3,000 Hz (-3 dB)
NoiseLess than 3 μV peak-peak for 0.05 to 70 Hz band
Electrode socketsTwo differential inputs (white) and one virtual ground (black).
1.5-mm touch-proof connectors (DIN 42802).
Auxiliary connector1. Positive supply voltage (+3 V to +5 V)
2. +Signal output
3. Ground
4. -Signal out
5. Negative supply voltage (-3 V to -5 V)
Dimensions (W x D x H)35 mm x 35 mm x 15 mm
Weight Approx. 25 g
Cable lengthApprox. 0.5 m
Miscellaneous
Suitable for use in MR scanner roomNo
Medical deviceNo
CE markingThe Brain Products GmbH confirms the electromagnetic compatibility (EMC) of this product according to the Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility.

The Brain Products GmbH confirms the RoHS compliance of this product according to Directive 2011/65/EU of the European Parliament and the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (recast published in the Official Journal of the European Union on 1 July 2011) as well as all its amendments up to and including the Commission delegated directive (EU) 2015/863 of 31 March 2015 (published in the Official Journal of the European Union on 4 June 2015).

Recommended add-ons

actiCHamp Plus & PowerUnit

actiCHamp Plus

BrainAmp w. PowerPack and BUA

BrainAmp

LiveAmp

LiveAmp

LiveAmp Sensor & Trigger Extension (STE)

Sensor & Trigger Extension (STE) for LiveAmp

BrainVision Analyzer