Sensor & Trigger Extension (STE) for LiveAmp
Adds physiological signals and trigger options to your mobile EEG recordings
Allows to add sensors to any of the 8 AUX inputs
Enables wired 8-bit input and 8-bit output triggering
Connects to and powers the receiver of our Wireless Trigger
LiveAmp Sensor and Trigger Extension: Adding physiological signals to your mobile EEG setup
Combining the LiveAmp with the LiveAmp Sensor and Trigger Extension (STE) makes it possible to add additional physiological signals to your mobile EEG research. All of this, thanks to the internal memory of the LiveAmp amplifier, completely independent from a recording computer.
The additional inclusion of sensor signals into your mobile EEG research with the LiveAmp is as easy and flawless as 1, 2, 3. Just connect the STE to the LiveAmp from one side and to a standard power bank (as used for any mobile phone) on the other side. Thanks to the included belt clip, you do not even need to worry about fixing the STE to the subject. All LiveAmp Sensor and Trigger Extension connections are compatible with all Brain Products sensors currently on the market.
In addition to the 8 auxiliary (sensor) inputs, the STE offers a connection possibility for 8 input triggers and a connection possibility for 8 output triggers via common standard 9 pin D-Sub connection sockets. The latter allows you to control external stimulators or other devices.
Sensor & Trigger Extension (STE) | Technical specifications |
---|---|
Number of AUX channels | 8 |
Input range of AUX channels | ±4.8 V |
Current supply at AUX inputs | Max. 80 mA in total (that is 1 x 80 mA or 8 x 10 mA or etc.) |
Sample rate of AUX inputs | The sampling rate is the same for all channels (LiveAmp and Sensor and trigger extension). Regarding channel numbers and sampling rates the same restrictions as mentioned for LiveAmp apply. |
Galvanic isolation of AUX inputs | AUX channels are galvanically isolated from the EEG/ExG channels of LiveAmp (isolation voltage 1,500 VDC). |
Trigger input | - Number of bits: 8 - Connector type: D-Sub, 9-pin, female - Low active (internal 10 kΩ pull-up resistor to Vcc) - TTL (LVTTL) signals, 0 to +5 V (+ 3.3 V) |
Trigger output | - Number of bits: 8 - Connector type: D-Sub, 9-pin, male - TTL (LVTTL) signals, 0 to +5 V (+ 3.3 V) |
Galvanic isolation of trigger in-/outputs | Trigger channels are galvanically isolated from the EEG/ExG channels of LiveAmp (isolation voltage 1,500 VDC / 1,080 VAC (for 1 s)). |
Current consumption | Without sensors: 100 mA With sensors: 100 mA plus the total current of the sensors |
Dimensions (W x D x H) | 11.7 cm x 7.6 cm x 3.0 cm |
Weight | < 130 g |
Power supply | From external battery pack (powerbank) via the galvanically isolated LiveAmp USB adapter. |
Length of cable to LiveAmp | 80 cm (31 in.) |
Required LiveAmp revision | LiveAmp Rev. 04 or higher |
Miscellaneous | |
Suitable for use in MR scanner room | No |
Medical device | No |
CE marking | The Brain Products GmbH confirms the electromagnetic compatibility (EMC) of this product according to the DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility. The Brain Products GmbH confirms the RoHS compliance of this product according to Directive 2011/65/EU of the European Parliament and the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (recast published in the Official Journal of the European Union on 1 July 2011) as well as all its amendments up to and including the Commission delegated directive (EU) 2015/863 of 31 March 2015 (published in the 0fficial Journal of the European Union on 4 June 2015). |
Recommended add-ons