TurboLink
Streams EEG data from the actiCHamp (Plus) within less than 1.5 ms via User Datagram Protocol (UDP)
Seamlessly integrates with your actiCHamp (Plus) and BrainVision Recorder setup
Enables connection to your preferred data client for data processing and real-time brain state-dependent protocols
Works extremely smoothly in combination with the bossdevice RESEARCH
TurboLink: Accessing actiCHamp (Plus) data within less than 1.5 milliseconds
An increasing number of research applications require online access to EEG data streams. For example, when signal features of the EEG are used to trigger TMS (Transcranial Magnetic Stimulation) pulses, or where algorithms in BCI (Brain Computer Interface) applications are used to provide immediate response. For these applications, minimum latency and high accuracy become increasingly important.
With TurboLink, we offer a solution to achieve exactly that: TurboLink streams EEG data from the actiCHamp (Plus) via a User Datagram Protocol (UDP) to your preferred data client, which is doing the data processing. The Recorder PC is used to configure actiCHamp (Plus) through TurboLink and to monitor and/or record the data in the BrainVision File Format for validation or offline analysis.
TurboLink | Technical specifications |
---|---|
Max. number of actiCHamp (Plus) amplifiers that can be connected | 1 |
Number of channels | Up to 160 (EEG) + 8 (AUX) |
Supported output sample rates to client | 500 Hz, 1000 Hz, 5000 Hz and 10000 Hz (for all channels numbers) |
Delay | Typical: 1 ms; Upper limit: 1.5 ms |
Data protocol | User Datagram Protocol (UDP) |
Input range of mains power supply | 100-240 VAC; 50-60 Hz |
Power supply for mini PC | 19 VDC; 40 W |
Network Adapter | Dual Gigabit (1 GBit/s) |
Dimensions (L x W x H) | Approx. 12.8 cm x 12.7 cm x 5.7 cm (ZOTAC ZBOX CI329 Nano or CI331 Nano) |
Weight | Approx. 1.5 kg |
Ambient conditions | |
Operating | Temperature: 10 °C to 40 °C (50 °F to 104 °F) Relative humidity: 45 % to 85 %, non-condensing Atmospheric pressure: 700 hPa to 1,050 hPa |
Storage and transport | Temperature: 0 °C to 40 °C (32 °F to 104 °F) Relative humidity: 45 % to 85 %, non-condensing Atmospheric pressure: 700 hPa to 1,050 hPa |
To prevent mechanical damage during transport, please pack the product in such a way, that it is not subject to vibration. |